Products
| Article number | 004-0-0017 |
| Operating principle | Non-dispersive infrared (NDIR) |
| Measured gas | CO₂ |
| Measurement range | 0.04–5%vol |
| Accuracy | ±(200ppm +10% of reading) |
| Operating range RH | <85 % RH |
| Operation range °C | <50 °C |
| Warm-up time | TBA |
| Response time | <2 minutes by 90% |
| Power supply | 4.5 - 5.25 V |
| Peak current | 300 mA |
| Average current | 30mA |
| Communication | Modbus protocol, UART |
| Outputs | TBA |
| Compliance | TBA |
| Maintenance | Maintenance free |
| Life expectancy | >15 years |
| Dimensions | 33.9 x 19.8 x 8.7 mm (L x W x H) |
| Weight | 8 g |
| Storage conditions | -40-70 °C |
Disclaimer : Please refer to product specification for the complete technical details.
| Article number | Product | Description |
| 004-0-0050 | S8 2% | For high CO2 concentrations |
| 004-0-0010 | S8 Commercial | Miniature, low power and versatile sensor for CO₂ sensing |
| 004-0-0056 | S8 Residential | For connection by pin headers (for ventilation control and CO2 monitoring) |
| 004-0-0017 | S8 5% | For very high CO2 concentrations |
| 004-0-0053 | S8 LP | For applications where both energy consumption and accuracy are critical factors |
S8 5%
S8 2%
Technical Description
Handling Manual
Senseair Development kit
Product Compliance
- Statement on EU REACH Regulation 1907/2006
- Senseair Conflict Minerals Statement
- Senseair Statement on PFAS
- Declaration on California Proposition 65
- Declaration of Conformity, S8
Calibration Certificate
| Article number | Product | Description |
| 00-0-0101 | SADK S8 & S88 | Senseair Development kit for S8 & S88. |