Article number |
006-0-0008 |
Operating principle |
Non-dispersive infrared (NDIR) |
Measured gas |
CO₂ |
Measurement range |
0–10 000ppm |
Accuracy |
±30 ppm ±3 % of reading1 |
Operating range RH |
<85 % RH |
Operation range °C |
<50 °C |
Warm-up time |
0 sec |
Response time |
30s |
Power supply |
3.05 - 5.5 V |
Peak current |
125 mA |
Average current |
1-34μA |
Communication |
I2C, UART |
Outputs |
Digital |
Compliance |
ANSI/ASHRAE Standard 62.1-2022, RESET Standard Grade A, WELL Building Standard® (WELL v2™) |
Maintenance |
Maintenance free |
Life expectancy |
>15 years |
Dimensions |
33.5 x 19.7 x 11.5 mm (L x W x H) |
Weight |
5 g |
Storage conditions |
-40 – 70°C |
- Note 1: ±75ppm Accuracy at 1500–2500ppm (ANSI/ASHRAE compliance)
Disclaimer : Please refer to product specification for the complete technical details.