Products
| Article number | 009-4-0003 |
| Operating principle | Non-dispersive infrared (NDIR) |
| Measured gas | CH₄ |
| Measurement range | 0–5%vol |
| Accuracy | ±0.25 %vol |
| Operation conditions |
0 – 50 °C 0 – 95% RH (non-condensing) |
| Power supply | 3.05 - 5.5 V |
| Peak current | 95 mA |
| Average current | 390μA |
| Communication | I2C, UART |
| Maintenance | Meintenance free |
| Life expectancy | > 15 years |
| Dimensions | 34 x 21 x 12 mm (L x W x H) |
| Weight | 5 g |
| Storage conditions | -40 - 85 °C |
Disclaimer : Please refer to product specification for the complete technical details.
| Article number | Product | Description |
| 009-4-0002 | Sunlight R290 | Refrigerant sensor with fast response time and long lifetime. |
| 009-4-0006 | Sunlight R290 PH — 10.92 | Sunlight R290 with 10.92 mm pin headers. |
| 009-4-0001 | Sunlight R32 & R454 A/B/C | Refrigerant sensor with fast response time and long lifetime. |
Sunlight Methane
Documentation for all Sunrise and Sunlight versions
Product Compliance
| Article number | Product | Description |
| 00-0-0108 | SADK Sunrise & Sunlight | Senseair Development Kit for Sunrise and Sunlight. |
What is Senseair Sunlight Methane?
Senseair Sunlight Methane is a compact NDIR methane sensor for measuring CH₄ up to 5 %vol. It is designed for product engineers who need reliable methane monitoring in a low-power sensor format.
What measurement range does Sunlight Methane support?
Sunlight Methane measures methane from 0–5 %vol. The standard range is 0–1.25 %vol and the extended range is 1.25–5 %vol.
Why use NDIR for methane monitoring?
NDIR is an optical sensing principle with immunity to poisoning and strong long-term stability. This makes it suitable for methane monitoring products where dependable behaviour over time is important.
Is Sunlight Methane maintenance-free?
Sunlight Methane is designed for maintenance-free operation when ABC is enabled. Senseair recommends discussing the application with Senseair to define a proper calibration strategy.
What communication interfaces does Sunlight Methane support?
Sunlight Methane supports UART and I²C. Modbus communication is available through UART.
Is Sunlight Methane suitable for low-power products?
Yes. Sunlight Methane is built for very low power consumption and supports configurable measurement behaviour, including single measurement mode.
What is single measurement mode?
In single measurement mode, the host system triggers each measurement when needed. This gives engineers more flexibility to optimise power consumption compared with continuous measurement mode.