Products
| Article number | 005-0-0001 |
| Operating principle | Non-dispersive infrared (NDIR) |
| Measured gas | CO₂ |
| Measurement range | 0–10 000ppm |
| Accuracy | ±50 ppm CO2 ±3 % of reading |
| Operating range RH | <85 % RH |
| Operation range °C | <50 °C |
| Warm-up time | TBA |
| Response time | TBA |
| Power supply | 2.9 - 5.5 V |
| Peak current | 125 mA |
| Average current | 31 μA |
| Communication | Modbus protocol, UART |
| Outputs | TBA |
| Compliance | |
| Maintenance | A host system counts ABC (Automatic Baseline Correction) period itself and has to write ABC command to the Calculation control byte when ABC period (eight (8) days) expires. |
| Life expectancy | > 15 years |
| Dimensions | 33.5 x 19.9 x 12.5 mm (L x W x H) |
| Weight | 8 g |
| Storage conditions | -40 – 70°C |
LP8
Technical Description
Handling Manual
| Article number | Product | Description |
| 00-0-0107 | SADK LP8 | Senseair Development kit for LP8. |