210317172719.jpg

Products

New
Product image S9 CO₂ 2%

S9 CO₂ 2%

Senseair S9 CO₂ 2% is an enclosed NDIR carbon dioxide sensor for agricultural and industrial control systems. It measures 0–20 000 ppm CO₂ and connects to compatible controllers through a linear 0–5 V output.

S9 includes an internal heating element designed to prevent condensation inside the sensor. Its epoxy-encapsulated electronics help protect against moisture, while the replaceable outer-filter cover makes servicing straightforward. The sensor can be replaced without disturbing the installed cabling or mounting bracket.

Applications include egg incubators and hatchers, poultry and livestock buildings, mushroom growing rooms, greenhouses and industrial monitoring equipment.

Defining attributes

  • Internal heating element for condensation prevention
  • 0–20 000 ppm CO₂ measurement range
  • Linear 0–5 V output
  • Epoxy-encapsulated electronics
  • IP65 protection with protective cover fitted
  • Replaceable outer-filter cover
  • Individually calibrated sensors

In egg incubators and hatchers, CO₂ measurement provides feedback for ventilation throughout incubation and hatching cycles. In poultry and livestock buildings, it helps ventilation systems respond to changing conditions around the animals. Dust, humidity and cleaning between production cycles make sensor protection and service access part of the installation requirements.

In mushroom growing rooms, ventilation removes CO₂ released by the crop while also affecting temperature and humidity. In greenhouses, CO₂ measurement provides feedback for enrichment control. S9 combines internal heating with protected electronics to support these applications within its specified operating conditions.

For industrial monitoring equipment, the 15–30 VDC supply and 0–5 V output allow connection to compatible control systems. Periodic zero calibration and a replaceable outer-filter cover support ongoing servicing, with an expected sensor lifetime of more than ten years.

Article number 099-16-0004
Operating principle Non-dispersive infrared (NDIR)
Measured gas CO₂
Measurement range 0–20 000 ppm
Accuracy ±300 ppm ±3% of reading
Operating range RH <95 % RH
Operation range °C <50 °C
Warm-up time <60 s
Response time <60 s
Power supply 15 - 30 V
Outputs Linear analogue voltage output
Maintenance Periodical calibration
Life expectancy >10 years
Dimensions 38 x 38 x 46 mm (L x W x H)1
Storage conditions -40–60 °C
Average power consumption <1 W
  1. Without connector

What is Senseair S9 CO₂ 2%?

Senseair S9 CO₂ 2% is an enclosed NDIR carbon dioxide sensor with internal heating for condensation prevention. It measures 0–20 000 ppm CO₂ and provides a linear 0–5 V output for integration into agricultural and industrial control systems.

What applications is S9 CO₂ 2% designed for?

S9 CO₂ 2% is designed for egg incubators and hatchers, poultry and livestock buildings, mushroom growing rooms, greenhouses and industrial monitoring equipment. Its protected construction and serviceable design support installations where dust, humidity and regular cleaning are part of the operating environment.

Why use S9 CO₂ 2% in egg incubators and hatchers?

Egg incubation and hatching require ventilation to follow changing conditions throughout the production cycle. S9 CO₂ 2% provides CO₂ feedback to compatible controllers, with protected electronics and a removable sensor body that simplifies replacement between production cycles.

Why use S9 CO₂ 2% in mushroom growing rooms?

Mushrooms release CO₂ as they grow. Ventilation needs to remove that build-up while maintaining the temperature and humidity required by the crop. S9 CO₂ 2% provides CO₂ feedback through its 0–5 V output. Its internal heating element is designed to prevent condensation inside the sensor.

What makes S9 CO₂ 2% suitable for demanding environments?

S9 CO₂ 2% combines a protective housing, epoxy-encapsulated electronics and an internal heating element designed to prevent condensation inside the sensor. A replaceable outer-filter cover supports servicing. The sensor has IP65 protection with the specified protective cover fitted, which must be used during cleaning.

Does S9 CO₂ 2% require maintenance?

S9 CO₂ 2% requires periodic zero calibration. Fit the protective cover during cleaning. If the outer filter is damaged, replace the green cover that carries it. If the inner filter is damaged, replace the sensor.

Does Senseair S9 CO₂ 2% have an internal heating element?

Yes. Senseair S9 CO₂ 2% contains an internal heating element designed to prevent condensation inside the sensor. Installation and operation must follow the temperature and humidity limits in the product specification.